Available 24/7 - No Overtime Charges, EVER!

Brandon

Rating

Reviews

Brandon has been in the HVAC industry for 11 years. He enjoys camping, fishing, and just about anything outdoors. Brandon’s favorite part of his job is meeting new people and fixing challenging problems. His smile is contagious and is always on his face. We love having such a happy technician and we hope you will too.

Name: Brandon

Local Reviews

Interstate Heating & Air Conditioning Rated 4.9 out of 5 stars based on 105 customer reviews

Map of Oklahoma City, OK

AWESOME Technician




Review of Interstate Heating & Air Conditioning

Brandon Nelson is very friendly, professional and efficient. He explained to me what the problem was, tested my A/C to make sure the problem was resolved.


Map of The Village, OK

AC not cooling after it had a pre-summer checkup.




Review of Interstate Heating & Air Conditioning

At first the tech said I needed to have freon added for $149. and also cost of a diagnosis call, $89.99. I told him I had already a diagnosis call and nothing was indicated as being needed and his office had said that there would be no charge for the diagnosis. I told him I would think on the freon. Brandon called back and said he went ahead and added nine oz. of freon and wouldn't charge for the diagnosis call. There was no charge for the service. That restored my faith in Interstate and the owners, Kai and Jamie.


Map of Oklahoma City, OK

Quick service




Review of Interstate Heating & Air Conditioning

Very happy with the experience.


Map of Norman, OK

Great everything




Review of Interstate Heating & Air Conditioning


Map of McLoud, OK

Service call




Review of Interstate Heating & Air Conditioning

Brandon is very courteous and knowledgable.


Map of Oklahoma City, OK

Great job




Review of Interstate Heating & Air Conditioning


Map of Warr Acres, OK

Excellent, as expected from Interstate.




Review of Interstate Heating & Air Conditioning

Brandon is a top-notch technician. He knows his business, cares about the satisfaction of the customer, and goes beyond the normal expectations to provide that satisfaction. Having once been an A/C service technician myself, I know what to look for, and I saw it all in Brandon. Interstate installed my system in 2012 and today was the first time I had any trouble ever. The condenser fan motor bushings finally wore out, and I know that kind of longevity is unusually good. Maybe I can get another 8 yrs from the new one!


Map of Edmond, OK

Great service, very courteous technicians




Review of Interstate Heating & Air Conditioning

Very pleased with their service. Highly recommend this company.


Map of Bethany, OK

Excellent service!




Review of Interstate Heating & Air Conditioning

Brandon was awesome! Fixed our a.c. in a timely manner, took time to check a few other things & listened to any questions & concerns. He didnt leave till he made sure things were all good.


Map of Oklahoma City, OK

Owner




Review of Interstate Heating & Air Conditioning

Great service


Brandon N.

Brandon N.

Arrived to no cool service call performed evaluation. System has caught on fire. Lots of damage to furnace. Evaporator coil has been leaking on furnace for a very long time. Extensive rusting and rotting on system due to many years of leaking. Concrete flues are illegal per code flue will need replacement. Furnace and coil over 40 years old due to age and condition. System will need replacing. Water on motor most likely caused fire. Due to liability and safety concerns I cannot repair this unit and replacement of system will be my recommendation. Collected diagnostic fee will apply towards system replacement if customer chooses to have work performed.

Near NW 29th St, Oklahoma City, OK 73107
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Found bad capacitor at condenser. Spoke to customer. Customer chose to replace capacitor. Installed new 55/7.5 capacitor. Tested amp draw it is in range. Refrigerant levels are in range. Changed customer supplied filters. System is cooling at this time.

Near NW 112th St, Oklahoma City, OK 73114
Brandon N.

Brandon N.

Arrived to service call and performed system evaluation evaluation. System is running but needed deep cleaning to condenser unit. Suggest tune up and customer had work performed. Tested capacitor and motor amp draw. Test compressor amp draw. Refrigerant levels are in range. System is cooling at this time. Suggest regular maintenance to keep system running as designed.

Near John Robert Dr, Oklahoma City, OK 73135
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Float switch was tripped. Cleared drain with nitrogen. Washed drain pan. Drain is draining at this time. System is cooling at this time.

Near Stone Ridge Dr, Edmond, OK 73034
Brandon N.

Brandon N.

Perform silver club air conditioner maintenance. Washed condenser. Refrigerant levels are in range. Changed filters. Test capacitor and motor amp draw. Test compressor amp draw. Coils are clean. Surge protectors are in working order. System is cooling as designed at this time.

Near Hatterly Ln, Norman, OK 73072
Brandon N.

Brandon N.

Arrived to condensation service call and performed system evaluation. We installed new evaporator coil less than 1yr ago. Some of tape around coil to plenum had blown apart and was causing plenum to drip some condensation. I repair tape and covered with mastic. I performed this as a warranty. But floor drain is backing up and most of condensation is coming from floor drain. Informed customer floor drain would need snaked.

Near S Villa Ave, Oklahoma City, OK 73159
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Found bad contactor switch. Customer chose to replace switch. Washed condenser so refrigerant could be Checked. Refrigerant in range. System is cooling at this time. 1 yr contactor warranty. It is very hot in house system will run along time before catching up. Attic could use more insulation.

Near Crabtree Cove, Midwest City, OK 73110
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Condenser is older and showing signs of age. Spoke to customer. At this time customer would like to replace capacitor and see what happens with unit. Install new capacitor. Unit started up amp draw not too bad at moment considering age of condenser. Refrigerant levels appear to be pretty close to in range superheat a little high but believe this to be because high temperature in house. System is cooling at this time.

Near NE Euclid St, Oklahoma City, OK 73117
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Found clogged drain line cut drain and used nitrogen to clear line. Re glued fittings and tested drain. System is draining at this time. Float switch is clear.

Near SW 163RD St, Oklahoma City, OK 73170
Brandon N.

Brandon N.

Arrived to call back performed system evaluation found system slightly low on r410a added 9 0z to system. Subcooling in range. System is cooling. Attic is very warm spoke to homeowner about insulation or whirlybird roof vents. System is cooling. No charges to customer at this time.

Near Stoneham Ave, The Village, OK 73120
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation on newer carrier system found bad capacitor. System still under warranty. Replaced capacitor free of charge to customer. System is cooling at this time.

Near Olde Tuscany Rd, Oklahoma City, OK 73169
Brandon N.

Brandon N.

Arrived to call performed system evaluation found air conditioner functioning properly. Customer had roof replacement recently and power roof vent was damaged. Due to power roof vent being broke attic temperature is very high. Customer is going to contact roofer and have them replace vent. I believe this will correct issue. No ac problems were happening before roof replacement. Will leave ticket open for now.

Near NW 13th St, Oklahoma City, OK 73107
Brandon N.

Brandon N.

Performed silver club air conditioner maintenance. Customer recently replaced filters. Washed condenser. Test capacitor and motor amp draw. Refrigerant levels are in range. System is cooling at this time.

Near E Wilshire Blvd, Jones, OK 73049
Brandon N.

Brandon N.

Came out to call. I was out to do the maintenance recently on the units. Customer said East unit had stopped working and was making a noise. I checked system over and found the system had locked itself out. I reset condenser and cooled down the compressor. System came back on but was freezing up quickly. I checked equipment in attic and found the variable speed motor not ramping up like its supposed to and was barely blowing any air. I reset module plugs and cycled it on again. Motor started and was operating properly. Discussed with customer about the module on the motor possibly malfunctioning, but it was operating after I reset the plugs. We talked over options, and customer wants to wait and see how it operates over the weekend. I will keep ticket open and have the model number on file in case I need to order it. Return to install previously recommended ecm motor replacement recommended by Isaac. Install new motor tested amp draw and verified motor is ramping up to correct speed.

Near Little Hickory, Arcadia, OK 73007
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Found bad condenser fan motor. Spoke to customer. Customer chose to replace. Installed new 825 rpm 1/6 hp motor complete with 50/7.5 capacitor. Tested amp draw it is in range. Compressor running at run load amps. Washed condenser. Refrigerant levels are in range. Indoor motor and capacitor in range. System is cooling at this time. 1yr motor warranty.

Near SW 92nd St, Oklahoma City, OK 73159
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Found system low on r410a refrigerant. System is older but working at this time. Customer does good job with maintenance blower and evaporator are clean. Condenser is clean. System is showing signs of age. Spoke options with customer. Customer chose to add refrigerant. Added 2lb r410a to system. System is cooling at this time. No guarantee on refrigerant due to age. If system becomes low in near future suggest replacement be considered.

Near Eric Dr, Oklahoma City, OK 73135
Brandon N.

Brandon N.

Performed non club tune up to system. Washed condenser, changed customer supplied filters. Refrigerant levels are in range. Customer showed interest in replacing condenser with heat pump. Current air handler is compatible with r410a gave estimates to customer. Customer will consider and call back if needed.

Near NW 22nd St, Oklahoma City, OK 73103
Brandon N.

Brandon N.

Performed non club tuneup. Customer will replace filters. Washed condenser. Test capacitor and motor amp draw. Test compressor amp draw. All amp draws are in range. Hard start kit is working. Refrigerant levels appear to be in range for current temperatures. System is cooling at this time.

Near SW 156th St, Oklahoma City, OK 73170
Brandon N.

Brandon N.

Performed silver club air conditioner maintenance. Washed condenser. Changed customer supplied filters. Test motor and capacitor. Test compressor. Amp draw and refrigerant in range. System is cooling at this time. Customer had pan treatment due to be changed. Customer chose to replace pan treatment.

Near Classen Blvd, Norman, OK 73071
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Found bad dual capacitor. Installed new capacitor and started system. All amp draw in range. Washed condenser so refrigerant could be accurately checked. Refrigerant levels are in range. Cycled unit multiple times. System is cooling at this time. Suggest regular maintenance to keep system running as designed. 1yr warranty on capacitor.

Near SW 151st St, Oklahoma City, OK 73170
Brandon N.

Brandon N.

Perform silver club air conditioner maintenance. Changed customer supplied filters. Test capacitor and motor amp draw. Washed condenser and tested compressor amp draw. Compressor amp draw is elevated but working at this time. Tested refrigerant levels they are in range. System is cooling at this time.

Near Benny Bruce St, Norman, OK 73026
Brandon N.

Brandon N.

Performed silver club air conditioner maintenance. Washed condenser coil. Tested capacitor and motor amp draw. Refrigerant levels are in range. Amp draw in range. Cycled unit multiple times. System is cooling at this time. Inside filter is dirty. Customer requires filters to be made due to unconventional filter size. Customer has contacted E.e.i and will replace filters today. System is cooling at this time.

Near Manor Dr, Oklahoma City, OK 73107
Brandon N.

Brandon N.

Arrived to service call on minisplit performed evaluation. Found condenser coil extremely dirty and inside unit frozen solid. Suggested tune up to customer. Customer had tune up performed. Cleaned filters and condenser coil. There is some ice on back of inside unit that cannot be reached and only time will thaw this area. Collected service fee and tuneup. Informed customer to let unit thaw and run system after unit thaws. Customer going to let thaw out over night and turn on system in morning. If unit doesn’t work correctly customer will have us come back out.

Near Hollywood Ave, Norman, OK 73072
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Found bad fuse at condenser. Replaced fuse. Started unit. Run load amps on this unit is 25. System is running at 39 and periodically climbing to 41 and fluctuated between those 2 numbers. System is wearing out and needs replacement. System will blow fuses again in near future. Do to age and condition of system I suggest complete system replacement. Customer will talk with building owner before making any replacement decisions. System is cooling at this time but could fail at anytime. The balance collected today will be applied towards new system if customer has replacement performed by us. System is cooling as well as can at this time.

Near N Shields Blvd, Moore, OK 73160
Brandon N.

Brandon N.

Arrived to no cool service call and performed system evaluation. Found bad dual capacitor. Customer chose to replace capacitor. Installed new capacitor and tested amp draw. Amp draw is in range. Refrigerant levels are in range. System is cooling at this time. 1yr capacitor warranty. Cycled unit multiple times. System is cooling at this time.

Near S Post Rd, Oklahoma City, OK 73150