Winter preventive check




Review of Interstate Heating & Air Conditioning

Very professional and courteous


Map of Harrah, OK

Annual Checkup




Review of Interstate Heating & Air Conditioning

Being on program well worth it.


Map of Oklahoma City, OK

Great




Review of Interstate Heating & Air Conditioning

On time, professional, knowledgeable. 5*


Map of Oklahoma City, OK

Excellent service!




Review of Interstate Heating & Air Conditioning


Blake S.

Blake S.

Arrived to the customer telling me what the problem was what he did to make it work and just had some ? Inspected and answer the ? Found a four ton for the down stairs which I did the math is correctly sized in return and a three ton on the up stairs which only has only a 14 inch return which is a total of 700 CFM system calls for a total of 1200 CFM recommend turning 14 into an 18 inch duct customer wants system to have heat tape installed after everything thaws and heat tape becomes available

Near SW 121st St, Oklahoma City, OK 73173
Blake S.

Blake S.

Found bad warranty heat kit gave customer the price got approval then got stuck customer helped me get in stuck and decided to wait on repair the system is not operational at this time.

Near Hillcrest Dr, Moore, OK 73160
Blake S.

Blake S.

Arrived to find thermostat unresponsive buttons/screen stuck tried to reset thermostat that did not work with approval replaced thermostat set up thermostat settings checked filters tenant changes them regularly 😁😁. Ran system through a cycle the system is operating correctly at this time

Near Sequoyah Ave, Moore, OK 73160
Blake S.

Blake S.

Arrived to find heat running and customer says heat cycle but was worried because fan was on all the time due to the humidifier calling but frozen customer had $25 gift card number4136234595671137 system is operating correctly at this time

Near SW 100th Terrace, Oklahoma City, OK 73139
Blake S.

Blake S.

Arrived and found filter plugged took filter out and reset system system fired watched run twenty min the filter was the issue customer said she would get the filter system operating correctly at this time

Near NE 10th St, Moore, OK 73160
Blake S.

Blake S.

Arrived and found system working only with one set of elements coming on pulled blower and found wiring harness not making a good connection but also found system ductwork to be installed incorrectly and short on return walked attic with customer and explained why and where it is incorrect and how it effects the system gave customer club options ran system for thirty min system seems to be running correctly at this time charged customer for test and verify and exsplained it is good for thirty day.

Near SE 89th St, Oklahoma City, OK 73150
Blake S.

Blake S.

Preformed heat preventative maintenance on 80% Lennox furnace cleaned flame sensor checked amps on all motors checked all safeties customer changes filters regularly 😁. The equipment is operating correctly at this time. Crawled entire attic and found All wyes to be coming apart and three slightly disconnected in sw corner there are too many wyes on the runs and the plenum is duct board and starting to fall apart but has air leaks in it now I recommend replacing the ductwork. This will prolong equipment life and obtain better comfort lower energy cost prevent break down informed customer how bad it has deteriorated and that the air he was half way aware of the issue and told him to let us know when they wanted to do the repairs

Near San Mateo Ct, Edmond, OK 73012
Blake S.

Blake S.

Preformed heat preventative maintenance on 80% down flow system checked all electrical components cleaned flame sensor checked amps on all motors did safety inspection saw no concerns customer is ready to flip her system from down flow to a horizontal in the attic due to all the sand and ground water entering the ductwork customer said after the ice storm her ducts sounded like shoes in the dryer. Crawled entire attic plenty of room customer will need a senior tech out to give an estimate while walking the attic I found a lack of insulation I recommended to Lisa while they where up there that it would be best to insulate at the same time the system is operating correctly at this time

Near NW 82nd St, Oklahoma City, OK 73132
Blake S.

Blake S.

Preformed heat preventative maintenance on electric air handler and heat pump. Tempature outside 14* degrees the heat pump would not operate checked capacitor on heat pump it was good checked amps of blower motor they where good inspected ductwork it looked good visually inspected dryer vent and found lint protruding from the seems this tells me there is a inner wall of debris and is the reason you have to run dryer twice to completely dry clothes which strains your dryer and causes a fire hazard recommend dryer vent cleaning inspected hot water tank customer informed me that there is enough hot water but a lack of water pressure informed customer this was due to sediment in the tank customer was ok with the hot water at this time informed her that we offer those services he system has surge protectors installed customer changes filters regularly 😁gave customer the filters. The system is operating correctly at this time.

Near Pinecrest St, Norman, OK 73071
Blake S.

Blake S.

Preformed heat preventative maintenance on two 80% down flow systems on each system checked amps on motors checked all electrical components preformed a safety inspection and found no issues visually inspected hot water tank and found that the main tank was 1991 asked customer if there was a lack of hot water he informed me there was and that he was moving soon and was thinking about replacement below is an estimate for a new tank and materials needed to bring up to code mr Matsumoto said he will call to schedule when he was ready both systems are operating correctly at this time. Changed all filters that customer provided.

Near Danfield Dr, Norman, OK 73072
Blake S.

Blake S.

Preformed fall service on 80% upflow furnace changed the filter cleaned flame sensor checked amps on motors checked all electrical components and furnace order of operation did safety check and found no concerns asked customer if they had a lack of hot water or pressure they said no and asked if laundry took longer to dry than they wher suppose to they said no system is operating correctly at this time

Near N Woodcrest Dr, Midwest City, OK 73110
Blake S.

Blake S.

Preformed heat preventative maintenance on 80%up flow furnace customer has high static media filter which she provided(customer has one filter left will need to order more after next visit) Checked all electrical components and safeties inspected blower wheel and evaporator customer is well insulated did a safety inspection and found no concerns. The system is operating g correctly at this time

Near Lonnie Ln, Moore, OK 73170
Blake S.

Blake S.

Preformed heat pm checked amps on all motor cleaned flame sensor the filter looked good but will need changed in the spring checked all electrical components and all components where within specs the system is operating correctly at this time. Inspected all ductwork and crawled entire attic and found the insulation to be extremely bare and in some locations no insulation. Recommend having insulation blown in to r38 national standard for our region and eligible for ogne rebate as well as tax credit for bringing up to regulation the insulation is the biggest concern next to the heat gain/loss from poorly installed ductwork lots of slack and dips in ductwork as well as many air leaks due to poorly being sealed found return air to be in adequate system is a 4 ton system you should have 400 CFM per ton you have a 4 ton system which should have 1600 CFM after performing a ductwork calculation I found that you are lacking 420 CFM which is over 1 ton of air if you were not bringing back four

Near Long Cir, Norman, OK 73071
Blake S.

Blake S.

Preformed heat preventative maintenance on heat pump system with aux heating elements checked amps of all elements which all drew 15amps each the blower capacitor was perfect at 7.5. Kurt changes filter regularly 😁😁. Went outside and on the heat pump check amps of motors capacitor is a 35/5 and read33.3 capacitor is weak at 32.9 and 4.9 of 5uf inspected operation of heat pump system is operating correctly at this time asked Kurt if he felt like he had enough hot water he responded with there’s never enough hot water explained about sediment in the tank a told him I would work up estimate for new tank.

Near Classen Blvd, Norman, OK 73071
Blake S.

Blake S.

Preformed fall service on two 80% furnaces on each furnace I cleaned the flame sensor checked amps on all motors both capacitors read 7.4 of 7.5uf amps where all within specs I saw no safety concerns. Both systems are running correctly at this time filters looked good

Near SW 34th St, Oklahoma City, OK 73179
Blake S.

Blake S.

Performed heater preventative maintenance cleaned the flame sensor changed the filter checked amps on all motors all where in specs capacitor was perfect at 12.5uf inspected blower wheel and evaporator both where clear of debris got in the attic and inspected ductwork and insulation home is well insulated the roof was recently replaced so inspected the flashings and found no issues or safety concerns the hot water tank is new and the dryer goes through the wall the system is operating correctly at this time.

Near Oaktree Terrace, Midwest City, OK 73130
Blake S.

Blake S.

Arrived and found system off turn system on and the order of operations was correct until it was time for gas valve to open. The gas valve is sticking I just touched the valve and system fired I did this several times to clarify In front of customer explained was was happening showed customer how to keep the heat going by touching the valve until Monday when the supply house opens and we can get the price and availability of the valve arrived with gas valve installed new gas valve cycled system three times and no fault occurred. The system is operating correctly at this time.

Near Republic Dr, Oklahoma City, OK 73135
Blake S.

Blake S.

Preformed heat pm on 4 ton hp zoned system checked amps on all motors and they where within spec compressor running 9.5 a of 20 capacitor read within spec and hp operation was correct customer changes filters regularly😁😁 the return air was correctly sized. The system is operating correctly at this time and our records show you are eligible for duct clean in one year. Discussed earlier recommendations and the customer is still considering them.

Near 3310 Rd, Harrah, OK 73045
Blake S.

Blake S.

Arrived and found system giving a code E0 which is ignition Locke out. Reset system and system fired correctly and ran almost an hour in this hour I tried to get system to fault and did not when I was putting the doors back on system decided to fault which then it faulted several times. The tenant said the owner had it serviced this year also went ahead and cleaned the flame sensor as a precautionary measure if it doesn’t fault it shows the flame sensor want cleaned as the time of maintenance. Recommended the blue service agreement and test and verify customer approved recommendations the test and verify is good for thirty day when I left the system was operating correctly. Also told customer his first visit would be in the spring.

Near N Harvey Pkwy, Oklahoma City, OK 73118
Blake S.

Blake S.

Arrived to blue shield plan customers home and found common wire behind the wall and installed new smart thermostat that customer provided went through and set up the time date schedule and WiFi system is operating correctly at this time

Near NW 40th St, Oklahoma City, OK 73118
Blake S.

Blake S.

Found system giving code 13 limit fault after further inspection I found the wires off the capacitor ran system through cycle system operating correctly at this time

Near SW 2nd St, Moore, OK 73160
Blake S.

Blake S.

Preformed fall service on 80% up flow furnace customer has 16x25x1 ez-flex filter that was due for replacement with approval replaced filter cleaned the flame sensor checked amps on all motors they where good the evaporator and blower wheel where clean asked customer about clothes taking longer to dry he said they do not ran system through a cycle. The system is operating correctly at this time.

Near Northridge Rd, Moore, OK 73160
Blake S.

Blake S.

Arrived to find a code 13 limit fault reset system and heat fired but not the fan. Troubleshot and determined that the brain in the ecm electronically controlled motor had faulted. Motor is under warranty got motor and installed and ran system through a cycle customer said he will cut in another return system operating correctly at this time

Near SW 1st St, Moore, OK 73160
Blake S.

Blake S.

Perform fall service on 80% downflow Lenix furnace clean the flame sensor checked amps on motors performed a safety inspection checked all electrical components the system is operating correctly at this time also inspected the insulation in the attic and found it to be in adequate and informed customer about ogne rebate for bringing insulation up to par. Did a ductwork calculation and found system lacking in return air the system is a four ton which needs 1600cfm and is only being supplied with 1275 CFM system is lacking 325 CFM of air which is almost a whole ton of air customer says master bedroom is too hot/cold increasing return air will also increase the supply air because you can only push the amount of air that is brought back through your return. (If you have a four ton system but aren’t bringing back four tons of air you don’t really have a four ton system. )recommend increasing 14 metal pipe to an 18 inch. Also asked customer about the dryer taking to long and she said ye

Near NE 140th St, Edmond, OK 73013
Blake S.

Blake S.

Preformed fall service on condensing furnace checked for proper drainage cleaned flame sensor checked amperage on all motors customer changes the filters regularly 😁😁 did a safety inspection the system has surge protectors installed 😁 the system is operating correctly at this time. The second is a heat pump checked capacitor it read within spec checked amps of motor and compressor found fan running 1.1 amps and the data plate says motor over amps at .7 the motor is over amping and needs replaced customer wants to hold off until spring tested operation of heat pump and tested heating element amps they looked good blower motor amps in the air handler looked good system operating correctly at this time this system also has surge protectors installed.